3310G Series DC Electronic Load(75 W~400 W / 800 W)
3310G
3310G
3310G_F
3311G
3312G
3314G
3315G
3316G
3317G
3317G_B
3317G_F
3317G_M
3317G_S
3319G
3319G_F
3319G_M
3300G+3310Gx4
3302G+3310G
3305G+3310G
3310G-3315G
Features
  • 5 digital V / A / W Meter can be displayed on Large LCD display simultaneously.
  • Flexible CC, CR, CV, CP, CC + CV , CP + CV , Dynamic and short circuit operation modes.
  • Built-in test modes include Battery Discharge, BMS, Fuse/Breaker Trip/Non-Trip, Short circuit, OCP, OPP test modes.
  • Not only CC, CR, and CP mode have parallel operation functions, but CV mode also has parallel operation functions.
  • Turbo mode can withstand up to 2 times the current and power electronic load within 1 sec. period,most fit Fuse/Breaker and BMS、Short circuit、OCP、OPP test.
  • Provide battery BMS protection test function.
  • Support MPPT CC、CR、CV test function for solar panel.
  • Short circuit duration can be set within short circuit test.
  • Can set the power-on status value.
  • Voltage meter display can be configured as polarity positive ”+”)or negative (”-”).
  • Synchronous parallel execution function(SYNC. Load on).
  • Can be configured in the Mainframe of 3302G〔Single Slot Mainframe〕、3305G〔Two Slot Mainframe〕or 3300G〔Four Slot Mainframe〕,each mainframe has up to 150 sets Store / Recall memory.
  • Optional programmable NTC Resistor (installed in 3302G/3305G mainframe).
  • Optional Interface : GPIB、RS232、USB、LAN.
  • Protection against V, I, W, and ℃.
  • Optional 9923 load current waveform generator to provide the battery actual discharge current waveform simulation.
MORE DETAIL CLOSE
  • Each 3310G Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, plug in 3302G / 3305G / 3300G mainframe with 150 sets Store / Recall memory which provides load set-up more efficiently, also can be controlled via RS232、EthernetUSB and GPIB interface.
  • The new Turbo mode is designed for overload or protection testing, which includes OCP, OPP, Short for AC/DC or DC / DC power source; Over Charge / Discharge and Short for Battery BMS protection; and Blow / Not Blow testing for Fuse, Breaker or PTC Current Protection Components.
  • Support Short, OCCP and OCDP protection tests for battery BMS protection testing, the peak current before protection and protection response time are measured.
  • BMS, Fuse, OCP and OPP single-key test functions on the load make test more efficient.
  • Dynamic can be simulated under CC, CP mode. The current Rise / Fall slew rate can be adjusted individually and there is an external signal input so that load can have a simulated Specific Load Current Waveform, optional 9923 Load Current Waveform Generator is able to support real current waveform testing.
  • SHORT duration setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
  • Programmable LOAD ON / OFF voltage, GO / NG meter check, Voltage meter display “ + or “ – “ is selectable and 150 sets Store / Recall larger memory is much advance feature for each different application.
  • 150 sets test parameter and status storage function can call the storage memory real time in accordance with the auto sequence requirement,at any time to tune out the stored memory for use.

 

Applications

 

  • Voltage / Current source
  • SMPS transient response
  • Voltage Source Current limit testing and battery emulation for Charger testing
  • Battery discharge capacity
  • Lithium battery BMS charge and discharge protection
  • Fuse, Breaker, PTC specification test
  • MPPT test function for solar panels
  • R&D, Quality Control
  • ATE system
  • Production testing

Standard Accessories

 

3310G to 3316G, 3318G, 3319G/3319G-M Qty
Power Cord 1
4 mm Banana Plug (Red) 1
4 mm Banana Plug (Black) 1
2 mm Banana Plug (Red) 1
2 mm Banana Plug (Black) 1
Hook Terminal Y Type Large size terminal 4
Hook Terminal Y Type Small size terminal 2

 

3317G/3317G-M Qty
Power Cord 1
M6 HEX. HEAD CAP SCREW, L = 16 mm 2
Nut M6 2
M6 Spring Washer 2
Gilded Washer FW6.7 x 12.7 x 1.0 2
Positive (Red) Braided wire 1
Negative (Black) Braided wire 1
2 mm Banana Plug (Red) 1
2 mm Banana Plug (Black) 1

 

Optional Accessories 

 

  • GPIB+RS232 interface
  • RS232 interface
  • GPIB interface
  • USB interface 
  • LAN interface
  • 9933 Remote Controller
  • NTC Optional function10 KΩ Simulator resistance100 Ω to 500 KΩ)
  • NTC Optional function100 KΩ Simulator resistance1 KΩ to 5 MΩ)
  • GPIB cable length 1 m
  • GPIB cable length 2 m
  • USB TYPE A to TYPE B cable length 1.8 m

Ordering information 

 

  • 3300G Four Solt Mainframe
  • 3305G Four Solt Mainframe
  • 3302G Four Solt Mainframe

 

Normal mode*

  • 3310G DC Electronic Load Module(60 V, 30 A, 150 W)
  • 3311G DC Electronic Load Module(60 V, 60 A, 300 W)
  • 3312G DC Electronic Load Module(250 V, 12 A, 300 W)
  • 3314G DC Electronic Load Module(500 V, 12 A, 300 W)
  • 3315G DC Electronic Load Module(60 V, 15 A, 75 W)
  • 3316G DC Electronic Load Module(80 V, 80 A, 400 W)
  • 3317G DC Electronic Load(80 V, 160 A, 800 W)
  • 3317G-M DC Electronic Load Module(80 V, 160 A, 800 W)
  • 3318G DC Electronic Load Module(500 V, 20 A, 400 W)
  • 3319G DC Electronic Load(500 V, 40 A, 800 W)
  • 3319G-M DC Electronic Load Module(500 V, 40 A, 800 W)

 

Turbo mode*

  • 3310G DC Electronic Load Module(60 V, 30 A, 300 W)
  • 3311G DC Electronic Load Module(60 V, 120 A, 600 W)
  • 3312G DC Electronic Load Module(250 V, 24 A, 600 W)
  • 3314G DC Electronic Load Module(500 V, 24 A, 600 W)
  • 3315G DC Electronic Load Module(60 V, 30 A, 150 W)
  • 3316G DC Electronic Load Module(80 V, 160 A, 800 W)
  • 3317G DC Electronic Load(80 V, 320 A, 1600 W)
  • 3317G-M DC Electronic Load Module(80 V, 320 A, 1600 W)
  • 3318G DC Electronic Load Module(500 V, 40 A, 800 W)
  • 3319G DC Electronic Load(500 V, 80 A, 1600 W)
  • 3319G-M DC Electronic Load Module(500 V, 80 A, 1600 W)

 

Application
The Application of 3310G DC Load NTC Simulation_E
2026-01-27
Application version.,EN 1.33 MB DOWNLOAD
Application
The Application of 3310G_6020 BMS Verification_E
2026-01-27
Application version.,EN 1.47 MB DOWNLOAD
Application
The Application of 3310G Series_E
2026-01-26
Application version.,EN 1.42 MB DOWNLOAD
PC Software
The PC Software of 3310G Seriel
2026-01-26
PC Software version., 2.88 MB DOWNLOAD
User Manual
The user manual of 3310G Series_E
2026-01-26
User Manual versionrK.,EN 33.1 MB DOWNLOAD
Brochure
The Brochure of 3310G Series_E
2026-01-26
Brochure version.,EN 1.78 MB DOWNLOAD
User Manual
The user manual of 3305G Solt Mainframe_E
2025-12-19
User Manual versionF.,EN 4.77 MB DOWNLOAD
User Manual
The user manual of 3302G Solt Mainframe_E
2025-12-19
User Manual versionE.,EN 4.62 MB DOWNLOAD
User Manual
The user manual of 3300G Solt Mainframe_E
2025-12-19
User Manual versionF.,EN 5.66 MB DOWNLOAD
USB Driver
The USB Driver of 3300G
2025-12-19
USB Driver version., 10.6 MB DOWNLOAD
LAN Driver
The LAN Driver of 3300G (for WIN7, WIN8, WIN10)
2025-12-19
LAN Driver version., 653 KB DOWNLOAD