Gwinstek would like to collect personal data provided and input by you on this website in order to provide services to you. Your data will be kept for as long as we need to process your request. You can learn more details Privacy Policy.
5 digital V / A / W Meter can be displayed on Large LCD display simultaneously.
Flexible CC, CR, CV, CP, CC + CV , CP + CV , Dynamic and short circuit operation modes.
Built-in test modes include Battery Discharge, BMS, Fuse/Breaker Trip/Non-Trip, Short circuit, OCP, OPP test modes.
Not only CC, CR, and CP mode have parallel operation functions, but CV mode also has parallel operation functions.
Turbo mode can withstand up to 2 times the current and power electronic load within 1 sec. period,most fit Fuse/Breaker and BMS、Short circuit、OCP、OPP test.
Provide battery BMS protection test function.
Support MPPT CC、CR、CV test function for solar panel.
Short circuit duration can be set within short circuit test.
Can set the power-on status value.
Voltage meter display can be configured as polarity positive ”+”)or negative (”-”).
Can be configured in the Mainframe of 3302G〔Single Slot Mainframe〕、3305G〔Two Slot Mainframe〕or 3300G〔Four Slot Mainframe〕,each mainframe has up to 150 sets Store / Recall memory.
Optional programmable NTC Resistor (installed in 3302G/3305G mainframe).
Optional Interface : GPIB、RS232、USB、LAN.
Protection against V, I, W, and ℃.
Optional 9923 load current waveform generator to provide the battery actual discharge current waveform simulation.
Each 3310G Series has its own control and display panel, CC / CR / CV / CP / Dynamic modes, plug in 3302G / 3305G / 3300G mainframe with 150 sets Store / Recall memory which provides load set-up more efficiently, also can be controlled via RS232、Ethernet、USB and GPIB interface.
The new Turbo mode is designed for overload or protection testing, which includes OCP, OPP, Short for AC/DC or DC / DC power source; Over Charge / Discharge and Short for Battery BMS protection; and Blow / Not Blow testing for Fuse, Breaker or PTC Current Protection Components.
Support Short, OCCP and OCDP protection tests for battery BMS protection testing, the peak current before protection and protection response time are measured.
BMS, Fuse, OCP and OPP single-key test functions on the load make test more efficient.
Dynamic can be simulated under CC, CP mode. The current Rise / Fall slew rate can be adjusted individually and there is an external signal input so that load can have a simulated Specific Load Current Waveform, optional 9923 Load Current Waveform Generator is able to support real current waveform testing.
SHORT duration setting and SHORT_VH, SHORT_VL setting function, also can measure Short Voltage and Current.
Programmable LOAD ON / OFF voltage, GO / NG meter check, Voltage meter display “ + ” or “ – “ is selectable and 150 sets Store / Recall larger memory is much advance feature for each different application.
150 sets test parameter and status storage function can call the storage memory real time in accordance with the auto sequence requirement,at any time to tune out the stored memory for use.
Applications
Voltage / Current source
SMPS transient response
Voltage Source Current limit testing and battery emulation for Charger testing
Battery discharge capacity
Lithium battery BMS charge and discharge protection