4013A & 4015A & 4016 &4016A AC / DC Digital Power Analyzer (Discontinued)
4013A
4013A
4013A_B
4015A
4016A
4016A_F
4016A_B
9942
Features
  • 4013A(300V / 20A)AC/DC Digitizing Power Meter
  • 4015A(500V / 20A)AC/DC Digitizing Power Meter(Includes THD measurement)
  • 4016 & 4016A AC / DC Digital Power Analyzer

4013A(300V / 20A)AC/DC Digitizing Power Meter (Limited Stock Available)

 

  • Suitable for ATE: 305V 20A, 6000W AC/DC Digital Power Meter
  • Voltage Range:30 / 305 Vrms;40 / 400Vdc
  • Current Range:0.02 / 0.2 / 2 / 20Arms、200Arms(for Inrush);0.02 / 0.2 / 2 / 20Adc、200Adc(for Inrush)
  • Measure AC / DC voltage, AC / DC current, AC / DC power,AC power factor, AC frequency, and Inrush Current
  • Measuring frequency range DC、40~70Hz
  • Meter update rate can be programmed
  • Inrush Delay / Period:0~99.9ms / 0.1~99.9s can be programmed to get accurate Inrush Current measurement
  • Measuring module: 1 ~ 4CH, standard is 4 channels option 1, 2, 3 Channel is available
  • The built-in internal low-pass filter (50KHz) can eliminate unnecessary high-frequency interference

 

  • 4013A Digital Power Meter is designed to measure the power line parameters of AC / DC and DC / DC power supply. It is suitable for AC / DC Adapter, Charger, Quick Charger, LED Driver and DC / DC Converter. It is also suitable for uninterruptible power supply UPS, Regulators AVR, Inverter, batteries, AC / DC power supply / components ... and other applications.
  • 4013A digital power meter contains 1 to 4 channels digital power meters, each power meter has a group of high-speed 12-Bits A / D Converter, sampling and converting the voltage and current signals respectively. After the conversion, the data is calculated by a high-speed 16-Bits processor. After the calculation is completed, the data is transmitted to the host processor and read the relevant information through the RS-232 interface.

 

4015A(500V / 20A)AC/DC Digitizing Power Meter

 

  • Suitable for ATE: 500V 20A, 10000W AC/DC Digital Power Meter。
  • Voltage Range:15 / 30 / 50 / 150 / 300 / 500Vrms
  • Current Range:0.02 / 0.05 / 0.2 / 0.5 / 2 / 5 / 10 / 20Arms、200Apeak(for Inrush)
  • 0.1% high accuracy
  • Measure AC / DC voltage, AC / DC current, AC / DC power, AC power factor, AC frequency, Inrush current and V/A Harmonic parameters.
  • Measure voltage / current harmonics up to 50th order, and total harmonic distortion .
  • Frequency range DC、40~70Hz。
  • Measuring module: 1 ~ 4CH, standard is 4 channels, option 1, 2, 3 Channel is available。
  • The built-in internal low-pass filter (50KHz) can eliminate unnecessary high-frequency interference
  • With AC, DC, AVR 3 sets of power input, through the control of choice of input power to achieve AC / DC or DC / DC test flexibility.
  • With 0 ~ 360º 200Apeak output switch, can control the output on / off angle, you can accurately measure the Inrush current.

 

  • 4015A Digital Power Meter is designed to measure the power line parameters of AC / DC and DC / DC power supply. It is suitable for AC / DC Adapter, Charger, Quick Charger, LED Driver and DC / DC Converter. It is also suitable for uninterruptible power supply UPS, Regulators AVR, Inverter, batteries, AC / DC power supply / components ... and other applications.
  • 4015A digital power meter has three input source selection switch internally, according to the test needs to program that one of as input of the power meter.
  • Each channel of 4015A digital power meter has a 200Apeak power MOSFET switch parallel relay switch as the output switch, it can adjustable output on / off and AC any angle, used to test the Inrush current and Hold up time.
  • 4015A digital power meter contains 1 ~ 4 channels digital power meters, each power meter has a group of high-speed 16-Bits A / D Converter, sampling the voltage and current signals respectively. After the conversion, the data is calculated by a high-speed DSP processor. After calculation is completed, the data is transmitted to the host processor and read the relevant information through the RS-232 interface.
  • The 4015A has a built-in 4-channel stand alone AC Source / AVR selector switch and output a 200Apeak, 0 ~ 360º ON / OFF high-speed switch that turns on the power to be tested one by one and accurately measures Inrush currents up to 200Apeak. 

 

 

4016 AC / DC Digital Power Analyzer

 

  • 6 Selectable Voltage Ranges:
20 Vpeak / 0.001V,40 Vpeak / 0.001V,80 Vpeak / 0.01V
200 Vpeak / 0.01V,400 Vpeak / 0.01V,800 Vpeak / 0.1V
  • 18 Selectable Current Ranges:
0.002 Apeak / 0.1uA
0.004 Apeak / 0.1uA
0.008 Apeak / 0.001mA
0.02 Apeak / 0.001mA
0.04 Apeak / 0.001mA
0.08 Apeak / 0.01mA
0.2 Apeak / 0.01mA
0.4 Apeak / 0.01mA
0.8 Apeak / 0.1mA
2 Apeak / 0.1mA
4 Apeak / 0.1mA
8 Apeak / 0.001A
10 Apeak / 0.001A
20 Apeak / 0.001A
40 Apeak / 0.001A
50 Apeak / 0.001A
100 Apeak / 0.01A
200 Apeak / 0.01A
 
  • Voltage/Current Frequency Range: DC, 20~1000Hz
  • Embedded high-speed DSP, and V/A 16 bits Analog/Digital converters to provide continuous gapless measurement with max sampling rate up to 409.6kHz
  • Input Range up to 800Vpeak / 200Apeak
  • corrent can be increased to 30Arms(option)
  • 2mA minimum current range & 0.1uA Current resolution
  • 0.0001uW minimum power resolution and 0.03W standby power integration mode are meet ENERGY STAR / IEC62301 requirement
  • Color TFT LCD digital numeral and graphic display
  • Display voltage, current by digital and graphics
  • Capable of meeting the IEC 61000-3-2 harmonics measurement requirements and up to 50th Harmonics resolution.
  • Data Logger mode:
·  Up to 256 records for Vrms / Arms / Watt / PF / VTHD measurements
·  External PC for no-limit records q'ty for long-term quality monitoring
  • Built-in power switch to control
·  The input signal ON / OFF angle (0~359̊) / 1°
·  Test period and repetition times up to 9999 times
·  Repeat test period can up to more than 138days
  • Inrush Current and Voltage measurement
  • Support external CT and PT measurement functions to expand the measurement range of current and voltage
  • Support external shunt measurement function: Can be used with Prodigit 7550A and 1000A to expand the higher measurement current and power integration Whr, Ahr measurement function demand
  • Optional Interface :GPIB、RS232、USB、LAN
  • Optional :9942 Measuring Fixture BOX
4013A AC / DC Digital Power Meter (1 Channel)
4013A AC / DC Digital Power Meter (2 Channel)
4013A AC / DC Digital Power Meter (3 Channel)
4013A AC / DC Digital Power Meter (4 Channel)

 

 

4015A

AC/DC Digital power meter

(Includes THD measurement)

(1 Channel)
4015A

AC / DC Digital Power Meter

(Includes THD measurement)

(2 Channel)
4015A

AC / DC Digital Power Meter

(Includes THD measurement)

(3 Channel)
4015A

AC / DC Digital Power Meter

(Includes THD measurement)

(4 Channel)

 

 

4016A AC / DC Digital Power Analyzer (800Vp, 20Arms / 200Ap)
User Manual
The user manual of 4013A
2026-03-17
User Manual versionB.,EN 1.77 MB DOWNLOAD
User Manual
The user manual of 4015A
2026-03-17
User Manual versionA.,EN 3.1 MB DOWNLOAD
User Manual
The user manual of 4016 & 4016A
2026-03-17
User Manual versionI.,EN 4.32 MB DOWNLOAD