[General]
Name=Conducted EN55011 Class A G2 (Avg)
Description=Conducted Dicturbance 0.15-30MHz
Regulation=EN55011 Class A G2 (Avg)
EMIMODE=Conducted
DETECTION=AVG
RBW=9KHz
Freq start=0.15
Freq stop=30
Ref level=107
Scale=10
[Band]
Band_1=0.15,0.5
Band_2=0.5,5
Band_3=5,30
[Limit 1]
Section_1=0.15,90,0.5,90
Section_2=0.5,76,5,76
Section_3=5,80,30,60