AEL-5000 AC/DC Load
AEL-5002-350_3272_image
AEL-5002-350_3272_image
AEL-5006-350_32711_image
AEL-5012-350_32702_image
AEL-5015-350_32703_image
AEL-5019-350_32704_image
AEL-5000 back
Features
  • CC, Linear CC, CR, CV, CP and AC Rectifier Load Mode
  • Frequency Range : DC, 40~440Hz
  • Turbo Mode for 2 Times the Current and Power of Electronic Load within 1 Second
  • Three Units Parallel up to 90kW and Three-phase △ or Y Load Connection Can be Synchronized Control by One Master Unit
  • Loading and Unloading Angle Control; 0~359 Degree is Settable
  • Positive Half-cycle or Negative Half-cycle Loading
  • Supports SCR/TRIAC Current Phase Modulation Waveforms,90 Degree Trailing Edge and Leading Edge
  • Optional Interface : GPIB、RS232、USB、LAN

GW Instek launches 20 models of the AEL-5000 series AC/DC electronic loads depending on the power range. The power range of a single unit is from 1875W to 22500W, and up to 8 units can be connected in parallel. The maximum power of single-phase parallel connection can reach 180kW, and the total power of 3-phase can reach 540kW, which are suitable for UPS, Inverter/Breaker, AC Power Source, Battery, Fuse/Breaker, DC Power Source and other applications.

The AEL-5000 series has built-in precision measurement circuits such as 16-bit A/D and DSP to provide accurate measurement items, which include voltage root mean square value (Vrms), current root mean square value (Arms), and watt value (Watt), volt-ampere (VA), crest factor (CF), power factor (PF), total harmonic distortion (THD), voltage total harmonic distortion (VTHD), current total harmonic distortion (ITHD) , peak current (Ipeak), maximum current (Amax), minimum current (Amin), maximum voltage (Vmax), minimum voltage (Vmin), time measurement. In addition, built-in test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse/Breaker Trip/Non-Trip, short circuit simulation, OCP, OPP and other test modes.

The AEL-5000 series has the Turbo mode (ON or OFF can be selected) design, which can increase the current and power of the electronic load by 2 times in one second. For test applications that require transient high power and large current such as transient overload test of protective components or short circuit of Fuse/Breaker and AC power supply, OCP and OPP tests etc.. The Turbo mode provides the most economical solution.

The AEL-5000 series also supports the Load On startup function (pre-set Load On). When the inverter or uninterruptible power supply is turned on, the series directly loads the set load current to verify that whether startup of the inverter or uninterrupted power supply connecting to the electrical appliance is stable. At the same time, the Load On start function can also set positive half cycle or negative half load to verify whether the output voltage of the inverter or uninterruptible power supply remains stable when the actual electrical appliance only has a positive half cycle or negative half cycle load current. Control load angle and unload angle can also be set (range 0~359 degrees) to verify the stability of the transient response of the inverter or uninterruptible power supply when the appliance is plugged in and unplugged. In addition, the series also supports SCR/TRIAC current phase modulation waveform, 90 degree Trailing Edge and Leading Edge settings.

For the application of the adjustable bandwidth (BW) function, when the bandwidth of the DUT does not match the bandwidth of the AEL-5000 series, there will be oscillations. Users can reduce the BW setting value accordingly to meet the response speed of the DUT. Inrush Current verifies whether the transient response of the inverter output voltage is stable when the electrical appliance is turned on (Inrush Current) and when the electrical appliance is suddenly connected (Surge Current).

The entire series of AEL-5000 provides over-voltage warning, over-current, over-power, and over-temperature protection. Analog Input terminal can control constant current, constant power and other working modes through external voltage. Vmonitor/Imonitor terminal is used to connect external voltage/current monitoring device. In addition, a variety of optional control interfaces are provided such as GPIB, RS-232, USB, and LAN to meet the needs of system integration.

 

 

 

Standard Accessories

HD-DSUB 15PIN Parallel wire

 

Optional Accessories

 

PEL-022  GPIB Card
PEL-023

 RS-232 Card

PEL-024

 LAN Card

PEL-025

 USB Card

PEL-028

 HANDLES, U-shaped handle (fixed to the bracket) (for AEL-5006/5008/5012/5015)

PEL-029

 HANDLES Rack accessories(for AEL-5002/5003/5004)

PEL-030

 GPIB+RS-232 Card

GTL-248

 GPIB Cable, 2m

GTL-250

 GPIB Cable, 0.6m

GTL-246

 USB Cable, 1.2m

 

 

AEL-5002-350-18.75

350V/18.75A/1875W

AC/DC Load

AEL-5003-350-28

350V/28A/2800W

AC/DC Load

AEL-5004-350-37.5

350V/37.5A/3750W

AC/DC Load

AEL-5006-350-56

350V/56A/5600W

AC/DC Load

AEL-5008-350-75

350V/75A/7500W

AC/DC Load

AEL-5012-350-112.5

350V/112.5A/11250W

AC/DC Load

AEL-5015-350-112.5

350V/112.5A/15000W

AC/DC Load

AEL-5019-350-112.5

350V/112.5A/18750W

AC/DC Load

AEL-5023-350-112.5

350V/112.5A/22500W

AC/DC Load

AEL-5002-425-18.75

425V/18.75A/1875W

AC/DC Load

AEL-5003-425-28

425V/28A/2800W

AC/DC Load

AEL-5004-425-37.5

425V/37.5A/3750W

AC/DC Load

AEL-5006-425-56

425V/56A/5600W

AC/DC Load

AEL-5008-425-75

425V/75A/7500W

AC/DC Load

AEL-5012-425-112.5

425V/112.5A/11250W

AC/DC Load

AEL-5015-425-112.5

425V/112.5A/15000W

AC/DC Load

AEL-5019-425-112.5

425V/112.5A/18750W

AC/DC Load

AEL-5023-425-112.5

425V/112.5A/22500W

AC/DC Load

AEL-5003-480-18.75

480V/18.75A/2800W

AC/DC Load

AEL-5004-480-28

480V/28A/3750W

AC/DC Load

3D Model
3D Model of AEL-5000​, STEP format
2022-02-15
3D Model version., 【Member Only】 14.73 MB DOWNLOAD
USB Driver
The USB Driver of AEL-5000
2021-11-26
USB Driver version., 2.88 MB DOWNLOAD
PC Software
AEL-5000 Series PC Software
2024-01-04
PC Software version1.2., 1.53 MB DOWNLOAD
LAN Driver
PEL-5000C, AEL-5000

LAN Driver

(for WIN7, WIN8, WIN10)
2021-08-26
LAN Driver version., 650 KB DOWNLOAD
LAN Driver
PEL-5000C, AEL-5000

LAN Driver(for WINXP)

2021-08-26
LAN Driver version., 454 KB DOWNLOAD
User Manual
The user manual of AEL-5000
2023-07-28
User Manual versionB.,EN 12.68 MB DOWNLOAD
LabVIEW Driver
AEL-5000 LabVIEW Driver (for LabVIEW 2009)
2021-03-23
LabVIEW Driver version1.0.0., 316 KB DOWNLOAD
Brochure
The brochure of AEL-5000 Series
2023-05-09
Brochure version.,EN 24.51 MB DOWNLOAD